Envío a LUKA en todos los libros que quieras  Ver más

menú

0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional
portada Design Optimization of Prosthesis Hip Joint using FEM and TAGUCHI (en Inglés)
Formato
Libro Físico
Idioma
Inglés
N° páginas
116
Encuadernación
Tapa Blanda
Dimensiones
22.9 x 15.2 x 0.7 cm
Peso
0.18 kg.
ISBN13
9786200115409

Design Optimization of Prosthesis Hip Joint using FEM and TAGUCHI (en Inglés)

Syed Junaid Ali (Autor) · Manish Dadhich (Autor) · Om Shankar Prajapati (Autor) · LAP Lambert Academic Publishing · Tapa Blanda

Design Optimization of Prosthesis Hip Joint using FEM and TAGUCHI (en Inglés) - Ali, Syed Junaid ; Dadhich, Manish ; Prajapati, Om Shankar

Libro Nuevo

$ 94.650

$ 131.460

Ahorras: $ 36.810

28% descuento
  • Estado: Nuevo
  • Quedan 100+ unidades
Origen: Estados Unidos (Costos de importación incluídos en el precio)
Se enviará desde nuestra bodega entre el Miércoles 17 de Julio y el Miércoles 24 de Julio.
Lo recibirás en cualquier lugar de Chile entre 1 y 3 días hábiles luego del envío.

Reseña del libro "Design Optimization of Prosthesis Hip Joint using FEM and TAGUCHI (en Inglés)"

Using Taguchi method total experiments are required are L16 which are simulated in ANSYS FEM solver (Version-14.5). Proper FEM simulation techniques are applied for these simulation cases and the modeling steps are also developed for this research study. After proper simulation of these cases two responses are selected to optimize this base design for further study. The two response selected from this study is von-misses stress and body weight. In present study various type of analysis is performed both cases like signal to noise ratio analysis, analysis of variance analysis, model equation generation, optimization of this model equation for stress and body weight of hip joint. Visual analysis is also present in this research study. All these major outcomes are present in this research study. Rank identification of factors are also present in this study. The signal to noise ratio analysis for stress shows that the best factor is ball diameter whereas worst factor is neck length of hip joint.

Opiniones del libro

Ver más opiniones de clientes
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes