portada Standard Reference Material 1750: Standard Platinum Resistance Thermometers, 13.8033 K to 429.7485 K (en Inglés)
Formato
Libro Físico
Idioma
Inglés
N° páginas
42
Encuadernación
Tapa Blanda
Dimensiones
28.0 x 21.6 x 0.2 cm
Peso
0.12 kg.
ISBN13
9781495924927

Standard Reference Material 1750: Standard Platinum Resistance Thermometers, 13.8033 K to 429.7485 K (en Inglés)

G. F. Strouse (Autor) · W. L. Tew (Autor) · Createspace Independent Publishing Platform · Tapa Blanda

Standard Reference Material 1750: Standard Platinum Resistance Thermometers, 13.8033 K to 429.7485 K (en Inglés) - Strouse, G. F. ; U. S. Department of Commerce-Nist ; Tew, W. L.

Libro Nuevo

$ 32.100

$ 44.590

Ahorras: $ 12.490

28% descuento
  • Estado: Nuevo
  • Quedan 100+ unidades
Origen: Estados Unidos (Costos de importación incluídos en el precio)
Se enviará desde nuestra bodega entre el Lunes 15 de Julio y el Lunes 22 de Julio.
Lo recibirás en cualquier lugar de Chile entre 1 y 3 días hábiles luego del envío.

Reseña del libro "Standard Reference Material 1750: Standard Platinum Resistance Thermometers, 13.8033 K to 429.7485 K (en Inglés)"

The Standard Platinum Resistance Thermometer (SPRT) is defined by the International Temperature Scale of 1990 (ITS-90) as the interpolating instrument for temperatures between 13.8033 K and 1234.93 K. This SRM concerns the calibration characteristics of a group of 20 capsule-type SPRTs within the range of temperatures between 13.8033 K and 429.7485 K. The platinum wire used for the construction of the resistor elements of this SRM was derived from platinum bar stock with a chemical purity of 99.999 % by weight. Each of the 20 units has been evaluated, certified, and calibrated according to the definitions of the ITS-90. The resistance characteristics of all 20 units have been measured at 11 fixed point temperatures from 4.22 K to 429.7485 K as well as at least 7 other intermediate points. The procedures used in performing the calibrations and the supplemental measurements are documented in this publication. The resulting analysis pertaining to each individual unit, as well as the SRM sample population as a whole, is presented in detail.

Opiniones del libro

Ver más opiniones de clientes
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes